Description

The HOBO UX120 Pulse Data Logger is a highly versatile, 4-channel energy data logger that combines the functionality of four separate data loggers into one compact unit. It enables energy management professionals – from energy auditors to building commissioners – to easily track building energy consumption, equipment runtimes, and water and gas flow rates. The HOBO UX120 Pulse Data Logger is available in a standard memory model (UX120-017) capable of 500,000 measurements and an expanded memory version (UX120-017M) capable of over 4,000,000 measurements.

Environment:
The UX120-017 Data Logger is for use inIndoor environments

Measurements:
The UX120-017 Data Logger supports the following measurements (sensors sold separately):

State, Event, Runtime or Pulses from a variety of sensors including energy and flow meters.



Features


Spesification

Inputs:
External Contact Input: Electronic solid state switch closure or logic driven digital signals to 24 V
Maximum Pulse Frequency: 120 Hz
Maximum State, Event, Runtime Frequency: 1 Hz
Bits: 4–32 bits depending on pulse rate and logging interval
Maximum Pulses Per Interval: 7,863,960 (using maximum logging rate)
Driven Logic Signal: Input Low: ≤ 0.4 V; Input High: 3 to 24 V
Absolute Maximum Rating: Maximum Voltage: 25 V DC
Minimum Voltage: -0.3 V DC
Solid State Switch Closure: Input Low: < 10 KΩ; Input High: > 500 KΩ
Internal Weak Pull-Up: 100 KΩ
Input Impedance: Solid state switch closure: 100 KΩ pull up; Driven signal: 4.5 KΩ
Minimum Pulse Width: Contact closure duration: 500 uS; Driven logic signal: 100 uS
Lockout Time: 0 to 1 second in 100 ms steps
Edge Detection: Falling edge, Schmitt Trigger buffer
Preferred Switch State: Normally open or Logic "1" state
Logging:
Resolution: Pulse: 1 pulse, Runtime: 1 second, State and Event: 1 State or Event
Logging Rate: 1 second to 18 hours, 12 minutes, 15 seconds
Time Accuracy: ± 1 minute per month at 25°C (77°F) (see Plot A on next page)
Battery Type: Two AA alkaline or lithium batteries
Battery Life: 1 year, typical with logging intervals greater than 1 minute and normally open contacts
Memory:
Memory UX120-017: 520,192 measurements (assumes 8-bit)
UX120-017M: 4,124,672 measurements (assumes 8-bit)
Download Type USB 2.0 interface
Download Time 30 seconds for UX120-017, 1.5 minutes for UX120-017M
Physical:
Operating Range Logging: -40° to 70°C (-40° to 158°F); 0 to 95% RH (non-condensing)
Launch/Readout: 0° to 50°C (32° to 122°F) per USB specification
Weight 149 g (5.26 oz)
Size 11.4 x 6.3 x 3.3 cm (4.5 x 2.5 x 1.3 inches)
Environmental Rating IP50
CE The CE Marking identifies this product as complying with all relevant
directives in the European Union (EU).