TT210
Feature
- Two measuring methods: magnetic induction (F) and eddy current (N)
- Magnetic induction (F) method is used to measure the thickness of non-magnetic coating on ferrous metal
- Eddy current (N) method is used to measure the thickness of non-conducting coating on non-ferrous materials
- Automatic recognition of substrate
- Automatic selection of measuring methods
- 5 statistical ways: Mean values / Max. values / Min. values / testing numbers.(No.) / standard deviations (S.DeV)
- Upper-lower limit setting and sound alarm
- Data output to printer or PC by RS232 cable
- 500 readings can be stored
- 2 measuring modes: continuous / single
- 2 stop ways: Manual/automatic
Spesification
Probe types |
F |
N |
|
Measuring methods: |
magnetic induction |
eddy current |
|
Measuring range: |
0 to 1250 μm |
0 to 1250 μm |
|
Minimum resolution: |
0.1μm |
||
Tolerance : |
One point calibration |
±(3%H+1) |
± (3%H+1.5) |
H means the thickness of tested piece |
|||
Two points calibration |
±[(1~3)%H+1] |
±[(1~3)%H+1.5] |
|
H means the thickness of tested piece |
|||
Measuring condition |
Min. curvature radius (mm) |
Convexity 1.5 |
Convexity 3 |
Min. testing area diameter (mm) |
Φ7 |
Φ5 |
|
Critical thickness of substrate |
0.5 |
0.3 |
|
Power supply |
Battery AAA 1.5V (2pcs) |
||
Working Temperature |
0-40°C |
||
Dimensions |
110mm×50mm×23mm |
||
Weight |
100g |