Telaire 7001 CO2 Sensor

 

The Telaire 7001 handheld carbon dioxide sensor features patented Absorption Infrared technology. Each sensor measures CO2 and temperature and can calculate and display real-time ventilation rates. When combined with the HOBO U12 or ZW Series it can record CO2, and when connected to an analog input on a H22, RX3000, or U30 Series it can record temperature and CO2. The Telaire comes with an adapter but also operates up to 70 hours on 4 AA batteries (not included). 


Feature

  • Record 0 to 2500 ppm when using the CABLE-CO2 and a U12 or ZW
  • Record 0 to 4000 ppm when using the CABLE-2070 and a H22 or U30
  • AC Power Adapter Included

Spesification

Measurement Range 
When using the CABLE-CO2 and a U12 or ZW: 0 to 2500 ppm
When using the CABLE-2070 and a H22 or U300 to 4000 ppm 

Telaire 7001 operating range: 32°F to 122°F (0°C to 50°C), 0 to 95% RH, non-condensing
Display resolution: ±1 ppm
Accuracy: ±50 ppm or 5% of reading, whichever is greater
Repeatability: ±20 ppm
Temperature dependence: ±0.1% of reading per °C or ±2 ppm per °C, whichever is greater, referenced at 25°C.
Pressure dependence: 0.13% of reading per mmHg (corrected via user input for elevation)
Response time: <60 seconds for 90% of step change
Warm-up time: <60 seconds at 72°F (22°C)
Calibration interval: 12 months Full factory calibration available by contacting GE Measurement & Control Solutions.
Battery type: Four AA batteries (not included)
Battery operation: 80 hours (alkaline)

External power supply specifications
AC/DC adapter (included)
Output: 6 VDC, 500mA output.
Power connector: Round barrel with 2.5mm ID , 5.5mm OD, 12mm long, center positive (+6 VDC), outer shell ground.

Inquiry

Name :
Company :
Address :
Email :
Handphone :
Subject :
Product Name :
Product Type :
Message :
   

Video

Tidak ada video untuk produk ini

Testimoni

Download PDF

Tidak ada file catalog untuk produk ini


Artikel Terkait dengan Produk Telaire 7001 CO2 Sensor


NEWSLETTER

 

TESTIMONIALS

B2TKS

B2TKS
Sangat jarang perusahaan seperti ini di Indonesia!  Mereka terus-menerus mengikuti perkembangan inovasi engineering test & measurement, “nyambung” berdiskusi teknis dan berpengalaman, memiliki visi pengembangan teknologi pengukuran, pengujian, inspeksi dan monitoring.(Dr.-Ing. Ir. May Isnan - NDT Specialist B2TKS-BPPT)

Chevron

Chevron
Tim kerja Alat Uji dapat diandalkan. Sangat bagus dalam implementasi di lapangan. Secara umum kami puas dengan services nya!(Andre - HSE Chevron)

BPPT

BPPT
Saya baru sekali ini bertemu perusahaan engineering yang eksis seperti ini di Indonesia.  Sangat terbantu dengan solusi yang diberikan, sangat memuaskan!(Muksin Saleh, ST., MT - Fuel Conversion and Pollution Control Specialist, B2TE - BPPT)

BALITBANG

BALITBANG
Sistem monitoring yang disuplai oleh Alat Uji adalah yang tertinggi ratingnya sampai dengan saat ini dibandingkan sistem lain yang pernah kami miliki, Dengan sistem monitoring dari Alat Uji, Pengujian kami jadi lebih terkontrol karena ada visualisasi di sistemnya. (Gatot Sukmara - Badan Penelitian dan Pengembangan, Departemen Pekerjaan Umum)

 
Alat Uji Alat Uji Alat Uji Alat Uji Alat Uji Alat Uji