• sales@alatuji.com

     

  • 021 8690 6777
    021 8690 6770
  • 0812 9595 7914 (Mr. Parmin)
    0813 1066 1358 (Ms. Eki)
    0812 8333 5497 (Mr. Muslim)
  • 0812 1248 2471 (Mr. Alfin)
    0819 4401 4959 (Mr. Arya)

Differential Air Pressure Transducer Sensor

 

The T-VER-PX3UL transducer can measure either air pressure or velocity with the flip of a switch. The PX3 is available in three installation configurations: duct, panel or universal. Duct and panel models have two pressure and velocity range options: 0-1" WC / 0-3,000 ft/min or 0-10" WC / 0-7,000 ft/min with seven field-selectable sub-ranges for pressure and eight for velocity. All variants are available with and without display. The PX3 has an IP65/NEMA 4 environmental rating.

 

Requires analog input option during RX3000 or U30 system configuration and use of a S-FS-CVIA when using the H22-001 data logger. When using a U12 data logger, this sensor requires an 0-5 Vdc analog input cable (CABLE-ADAP5) and external power provided by an AC adapter (AC-SENS-1).


Feature

  • Switch-selectable ranges and scales reduce setup time
  • High reliability sensor technology for long-term maintenance-free operation
  • Monitors positive and negative pressure for application versatility

Spesification

  • Media Compatibility Dry air or inert gas
  • Input Power 12-30VDC, or 24VAC nominal
  • Output Field-selectable: 2-wire, loop-powered 4-20mA (DC only, clipped and capped) or 3-wire 0-5V/0-10V
  • Pressure Ranges: Unidirectional: 0.1/0.25/0.5/1.0” W.C. F.S. (25 pa/50 pa/100 pa/250 pa, F.S.), switch selectable; Bidirectional: ±0.1/±0.25/±0.5/±1.0” W.C. F.S. (±25 pa/±50 pa/±100 pa/±250 pa, F.S.), switch selectable
  • Response Time Standard: T95 in 20 sec, Fast: T95 in 2 sec, switch selectable
  • Mode Unidirectional or bidirectional, switch selectable
  • Display (option) Signed 3-1/2 digit LCD, indicates pressure, overrange indicator
  • Proof Pressure 3 psid (20.6kPa)
  • Burst Pressure 5 psid (34.5kPa)
  • Accuracy ±1% F.S. of selected range (combined linearity and hysteresis)
  • Temperature Effect 1" 0.05%/°C; 10"
  • Zero Drift (1-year) 1" 2.0% max.
  • Zero Adjust Pushbutton auto-zero and digital input (2-pos terminal block)
  • Operating Environment 0°- 60°C (32° to 140°F); 0 to 90% RH non-condensing
  • Fittings Brass barb; 0.24” (6.1mm) o.d.
  • Physical UL 94 V-O Fire Retardant ABS

Inquiry

Name :
Company :
Address :
Email :
Handphone :
Subject :
Product Name :
Product Type :
Message :
   

Video

Tidak ada video untuk produk ini

Testimoni

Download PDF

Tidak ada file catalog untuk produk ini


Artikel Terkait dengan Produk Differential Air Pressure Transducer Sensor


NEWSLETTER

 

TESTIMONIALS

B2TKS

B2TKS
Sangat jarang perusahaan seperti ini di Indonesia!  Mereka terus-menerus mengikuti perkembangan inovasi engineering test & measurement, “nyambung” berdiskusi teknis dan berpengalaman, memiliki visi pengembangan teknologi pengukuran, pengujian, inspeksi dan monitoring.(Dr.-Ing. Ir. May Isnan - NDT Specialist B2TKS-BPPT)

Chevron

Chevron
Tim kerja Alat Uji dapat diandalkan. Sangat bagus dalam implementasi di lapangan. Secara umum kami puas dengan services nya!(Andre - HSE Chevron)

BPPT

BPPT
Saya baru sekali ini bertemu perusahaan engineering yang eksis seperti ini di Indonesia.  Sangat terbantu dengan solusi yang diberikan, sangat memuaskan!(Muksin Saleh, ST., MT - Fuel Conversion and Pollution Control Specialist, B2TE - BPPT)

BALITBANG

BALITBANG
Sistem monitoring yang disuplai oleh Alat Uji adalah yang tertinggi ratingnya sampai dengan saat ini dibandingkan sistem lain yang pernah kami miliki, Dengan sistem monitoring dari Alat Uji, Pengujian kami jadi lebih terkontrol karena ada visualisasi di sistemnya. (Gatot Sukmara - Badan Penelitian dan Pengembangan, Departemen Pekerjaan Umum)

 
Alat Uji Alat Uji Alat Uji Alat Uji Alat Uji Alat Uji