SoundAdvisor Sound Level Meter Model 831C
The SoundAdvisor Model 831C Sound Level Meter is designed to make noise measurement easy. Due to its color display, connectivity, extensive software features and small form factor the SoundAdvisor is an ideal choice for handheld operation. Attended measurements are simplified, with the ability to control and monitor data via any PC or mobile device with a standard web interface. Designed with the acoustic professional in mind, the SoundAdvisor offers an elegant solution for complex needs in an easy to use system.
Feature
- Connectivity Is Key – Cellular, WiFi, and wired networking are all available to you when using the SoundAdvisor. The meter can even serve as its own WiFi hotspot.
- Many Platforms, Same Controls – Whether you are setting up a test on the meter, checking in remotely from your laptop, or receiving an alert to your smartphone, you’ll be working with the same interface and menus across all platforms
- Customizable for Your Application – From complete outdoor monitoring kits to a low noise option to automatic event detection, the SoundAdvisor is designed to help meet your testing needs
- LCD Color Interface – A full color user interface allows you to interpret data more easily, right from the meter
As with any device from Larson Davis, a thoughtful design process ensures that your needs are met from international standards to functionality.
- IEC 61672-1:2013, ANSI S1.4-2014 Class 1 integrating sound level meter
- Real-time frequency analysis in 1/1 and 1/3 octave bands, compliant
with IEC 61260:2014 and ANSI S1.11-2014 Class 1 - >120 dB dynamic range
- 2 GB internal memory, expandable by USB
- Full range AC output
- Available Low noise option (831C-LOWN)
Spesification
STANDARDS | ||
---|---|---|
The Model 831C meets the specifications of the following standards: | ||
Sound Level Meter Standards | ||
IEC61672-1 Ed. 2.0 (2013) Class 1, Group X |
||
IEC60651 Ed 1.2 (2001) plus Amendment 1 (1993-02) and Amendment 2 (2000-10) Type 1, Group X |
||
IEC60804 (2000-10) Type 1, Group X |
||
ANSI S1.4-2014 Class 1 |
||
ANSI S1.43-1997 Type 1 |
||
DIN 45657 |
||
Octave Filter Standards (Option 831C- OB3) |
||
IEC61260 Ed. 2.0 (2014) Class 1, all filters |
||
ANSI S1.11-2014 Class 1, all filters |
||
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use | ||
2006/95/EC Low Voltage Safety Directive |
||
IEC 61010-1 Ed. 3.0 (2010-06) |
||
EMC Immunity and Emission |
||
2004/08/EC EMC Directive |
||
IEC 61326-1 Ed. 2.0 (2012-07) |
||
IEC 61672-1 Ed. 2.0 (2013-09) |
||
FCC Title 47 CRF Part 15, Class B |
SPECIFICATIONS | ||||
---|---|---|---|---|
General | ||||
Reference Level |
114.0 dB re. 20 µPa |
|||
Reference Level Range |
Single large range for SLM measurements |
|||
Reference Frequency |
1000 Hz |
|||
Reference Direction |
0° is perpendicular to the microphone diaphragm |
|||
Operating Temperature |
≤ ± 0.5 dB variation between -22 °F to +122 °F (-30 °C to 60 °C) |
|||
Storage Temperature |
-22 °F to 158 °F (-30 °C to 60 °C) |
|||
Humidity |
≤ ± 0.5 dB variation from 25% to 90% relative humidity at 104 °F (40 °C) |
|||
Equivalent Microphone Impedance |
12 pF |
|||
Digital Display Update Rate |
Four times per second (0.25 sec between updates). First display indication is available 0.25 seconds after initiation of a measurement. |
|||
Effect of an Extension Cable |
None up to 200 ft (61 m) with EXCxxx cable |
|||
Approvals |
CE, ROHS, WEEE |
|||
Extended Weather Options |
-40 °F to +158 ºF (-40 °C to +70 ºC) operation with CER-831-E |
|||
Physical | ||||
Length with Microphone and Preamplifier |
11.35 in |
29.0 cm |
||
Length, Instrument Body Only |
8.8 in |
22.4 cm |
||
Width |
2.8 in |
7.1 cm |
||
Depth |
1.6 in |
4.1 cm |
||
Weight with Batteries, No Preamplifer or Microphone |
17.3 oz |
490 g |
||
Weight with Batteries, Preamplifer, and Microphone |
18.8 oz |
532 g |
||
Sound Level Meter Specifications | ||||
Averaging (Integration Method) |
Linear or Exponential |
|||
Time Weightings |
Slow, Fast,or Impulse |
|||
Frequency Weightings |
A, C, and Z |
|||
Peak Detector Frequency Weighting |
A, C, or Z |
|||
Gain |
0 dB or +20 dB |
|||
Sample Rate |
51,200 Hz |
|||
Peak Rise Time |
30 µs |
|||
Metrics Measured |
Leq, Lmax, Lmin, Lpeak, Ln (6 values), LDN, LDEN, LCeq – LAeq |
|||
Resolution Specifications | ||||
Levels |
0.1 dB |
|||
Elapsed Time |
0.1 s |
|||
Real Time Clock |
1 s |
|||
Calendar |
Through January 1, 2038 |
|||
Integration Time | ||||
Time Averaged Levels and Sound Exposure Levels |
||||
Minimum |
0.1 s |
|||
Maximum with Daily Autostore Enabled |
Unlimited |
|||
Maximum with Daily Autostore Disabled |
> 23 days with error < 0.5 dB |
|||
Broadband Noise Levels | ||||
Self-generated Electrical Noise |
0 dB Gain |
20 dB Gain |
||
Weighting |
Typical (dB) |
Max (dB) |
Typical (dB) |
Max (dB) |
A |
13 |
15 |
6 |
10 |
C |
15 |
22 |
12 |
16 |
Z |
22 |
25 |
19 |
26 |
Self-generated Total Noise |
0 dB Gain |
20 dB Gain |
||
Weighting |
Typical (dB) |
Max (dB) |
Typical (dB) |
Max (dB) |
A |
18 |
19 |
17 |
17 |
C |
18 |
23 |
17 |
19 |
Z |
23 |
26 |
21 |
26 |
Note: Combination of the electronic noise and the thermal noise of the 377B02 microphone at 68 °F (20 °C) measured in a sealed and vibration isolated cavity with an averaging time of 60 seconds. Electronic noise of the instrument with an ADP090 (12 pF) in place of the microphone highest anticipated self-generated noise. |