Temperature - Relative Humidity (RH) Data Logger - HOBO - LCD U14-001

 

HOBO U14 data logger menampilkan, merekam, dan memberikan pemberitahuan alarm tentang kondisi suhu dan kelembaban. Menerima pemberitahuan alarm dari luar dengan Auto Dialer opsional atau Remote Audible Alarm. Alat ini sangat cocok digunakan di lingkungan manufaktur, pemrosesan, dan penyimpanan dimana pemantauan dan dokumentasi yang dapat diandalkan mengenai kondisi relatif suhu dan kelembaban relatif yang kritis.


Feature

  • Waktu download data USB lebih cepat
  • Resolusi sensor suhu / resolusi debu yang lebih baik
  • Tampilan Real-time Temperature dan Relative Humidity
  • Tampilan dan output alarm memastikan laporan tepat waktu mengenai kondisi out-of-range
  • Dua model yang bisa dipilih - Suhu Internal / Kelembaban Relatif Suhu eksternal atau Temperatur / Kelembaban Relatif
  • Opsional Remote Alarm dan Autodialer
  • Kasus pelindung opsional untuk lingkungan basah atau kondensasi
  • Kompatibel dengan software HOBOware dan HOBOware Pro untuk setup logger, grafik dan analisis

Spesification

Environmental

  • Operating temperature range -20°C to +50°C, (-4°F to +122°F) , 0 to 100% RH non-condensing
  • Operating relative humidity range 0 to 95%, non-condensing, noncorrosive environment

Logger Capabilities

  • Capacity:
    Temp and RH: 21,500 measurements
    Temp Only: 43,000 measurements
  • Software-selectable sampling intervals: 1 second up to 18 hours, recording times up to 1 year
  • Programmable start time/date
  • Recording modes: Stop when full
  • Launch Modes: Immediate, Delayed
  • Nonvolatile EEPROM memory retains data even if batteries fail

LCD

  • Size: 33 x 50.8 mm (1.3 x 2 inches)
  • Displays temperature and relative humidity simultaneously
  • Displays °C or °F (selectable within host software)
  • Displays memory remaining and battery level
  • Displays flashing ALERT for out-of-limits conditions (selectable within host software) and stops flashing on offload or return to normal range.

Alarms

  • High and low set points for both temperature and relative humidity
  • Selectable delays for each set point
  • Alert conditions reset on offload or return to normal range.
  • Selectable Contact Relay: Normally Closed or Normally Open
  • Contact rating: 48VDC, 1A max
  • Contact resistance: less than 1 Ohm
  • Wire size range is 22AWG to 14AWG
  • 0% Low Battery Range Communications
  • Offloads data to PC or U-Shuttle via USB cable
  • Readout full logger (64K) in less than 30 seconds

Timekeeping

  • Time accuracy: ±1 minute per month at 20°C (68°F).

Power

  • 3 AAA Alkaline batteries, user-replaceable

Size/Weight

  • 125 x 92 x 31 mm (4.9 x 3.6 x 1.2 inches)
  • 170 g (6.0 oz) with batteries

Internal 12-Bit Temperature Sensor

  • Measurement range: -20°C to 50°C (-4°F to 122°F)
  • Accuracy: ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F); ±0.13°C (0.24°F) typical
  • Resolution: 0.02°C @ 25°C (0.04°F @ 77°F)
  • Response time: 15 minutes (to 90% in airflow of 1 m/sec)
  • Temperature Accuracy Drift: Negligible

Internal 12-Bit Relative Humidity Sensor

  • User replaceable
  • Measurement range: 0-100% RH, -20 to 50°C (-4 to 122°F)
  • Accuracy: ±2.5% from 10% to 90% RH (typical), to a maximum of ±3.5% including hysteresis
  • Resolution: 0.03°C RH @ 25°C (0.05° at 77°F)
  • Response time to 90%: 2 minutes (to 90% in airflow of 1 m/sec)
  • Accuracy Drift: <2% over 5 years typical
  • Hysteresis: 1% typical

External Sensors

  • For External Sensor Specifications, see the sensor's user manual.

Battery Life

  • The batteries will last one year in typical conditions (logging intervals of ? 1 minute with weekly offloads and average temperatures greater than 10°C or 50°F). Frequent offloads and/or extreme temperatures will reduce battery life.
  • At temperatures below freezing (0°C or 32°F), batteries will typically require replacement every six months. In these conditions the battery level bar graph should be checked regularly.

Inquiry

Name :
Company :
Address :
Email :
Handphone :
Subject :
Product Name :
Product Type :
Message :
   

Video

Tidak ada video untuk produk ini

Testimoni

Download PDF

Tidak ada file catalog untuk produk ini


Artikel Terkait dengan Produk Temperature - Relative Humidity (RH) Data Logger - HOBO - LCD U14-001


NEWSLETTER

 

TESTIMONIALS

B2TKS

B2TKS
Sangat jarang perusahaan seperti ini di Indonesia!  Mereka terus-menerus mengikuti perkembangan inovasi engineering test & measurement, “nyambung” berdiskusi teknis dan berpengalaman, memiliki visi pengembangan teknologi pengukuran, pengujian, inspeksi dan monitoring.(Dr.-Ing. Ir. May Isnan - NDT Specialist B2TKS-BPPT)

Chevron

Chevron
Tim kerja Alat Uji dapat diandalkan. Sangat bagus dalam implementasi di lapangan. Secara umum kami puas dengan services nya!(Andre - HSE Chevron)

BPPT

BPPT
Saya baru sekali ini bertemu perusahaan engineering yang eksis seperti ini di Indonesia.  Sangat terbantu dengan solusi yang diberikan, sangat memuaskan!(Muksin Saleh, ST., MT - Fuel Conversion and Pollution Control Specialist, B2TE - BPPT)

BALITBANG

BALITBANG
Sistem monitoring yang disuplai oleh Alat Uji adalah yang tertinggi ratingnya sampai dengan saat ini dibandingkan sistem lain yang pernah kami miliki, Dengan sistem monitoring dari Alat Uji, Pengujian kami jadi lebih terkontrol karena ada visualisasi di sistemnya. (Gatot Sukmara - Badan Penelitian dan Pengembangan, Departemen Pekerjaan Umum)

 
Alat Uji Alat Uji Alat Uji Alat Uji Alat Uji Alat Uji