Auto Range Digital AC/DC Clamp Meter ACM03
Feature
* Auto range
* Overrange protection is provided for all ranges
* Maximum voltage between terminals and earth ground:1000V DC or 750V rms AC
* Operating altitude: max.2000 meters(7000 ft.)
* Display: 4000 counts with analog bar LCD display
* Maximum value display: 4000 digits
* Polarity indication: automatic, "-" for negative polarity
* Overrange indication:"OL" or "-OL"
* Converter Rate: 3 times/sec; Bar graph: 30 times/sec
* Unit indication: function and unit
* Auto power off time: 15 minute
* Operating power: 1.5Vx3AAA batteries
* Battery low indication
* Temperating factor:<0.1xaccuracy/°C
* Operating temperature: 0°C to 40°C (32°F to 104°F )
* Storage temperature: -10°C to 50°C (10°F to 122°F )
* Dimension: 208x78x35mm
* Weight: approx. 340g(including batteries)
Spesification
Specifications |
Range |
Accuracy |
|
DC Voltage |
400mV/4V/40V/400V |
±(0.8%+3) |
|
AC Voltage |
4V/40V/400V/600V |
±(1.0%+5) |
|
AC Curren |
40A/400A |
±(3.0%+10) |
|
DC Current |
40A/400A |
±(3.0%+10) |
|
Resistance |
400Ω/4kΩ/40kΩ/400kΩ/4MΩ40MΩ |
±(0.8%+3) |
|
Capacitance |
400nF/4μF/40μF/400μF/4000μF |
±(4.0%+5) |
|
Frequency |
10Hz~10MHz |
±(0.5%+2) |
|
Duty cycle |
10%~95% |
±(3.0%+2) |
|
Feature |
|||
Display |
4000 Counts |
||
Auto and manual range |
Yes |
||
Data hold |
Yes |
||
Work light |
Yes |
||
Diode test |
Yes |
||
Max/Min Value hold |
Yes |
||
Continuity |
Yes |
||
Back light |
Yes |
||
General |
|||
Power supply |
1.5V(AAA)x3 Batteries |
||
Weight |
Approx 245g |
||
Size |
280mmx78mmx35mm |
||
Jaw Size |
Ø26mm |
||
Safety Rating |
CE CAT.III600V |
Inquiry