• sales@alatuji.com

     

  • 021 8690 6777
    021 8690 6770
  • 0812 9595 7914 (Mr. Parmin)
    0813 1066 1358 (Ms. Eki)
    0812 8333 5497 (Mr. Muslim)
  • 0812 1248 2471 (Mr. Alfin)
    0819 4401 4959 (Mr. Arya)

Conductivity/Salinity Data Logger HOBO - U24-002-C

 

Conductivity/Salinity

The HOBO U24-002-C is a cost-effective data logger for measuring salinity, conductivity and temperature in saltwater environments with relatively small changes in salinity (±5,000 μS/cm) such as saltwater bays, or to detect salinity events such as upwelling, rainstorm, and discharge events. It can also be used to gather salinity data for salinity compensation of HOBO U26 Dissolved Oxygen logger data.

Note: When monitoring salinity in waters with more than +/-5,000 uS/cm variation, refer to the accuracy shown in Plot C in the product specifications to determine if the accuracy is acceptable for your needs. Monthly field calibration readings are typically required to achieve the best accuracy.

Environment:
The U24-002-C Data Logger is for use inOutdoor and Underwater environments

Measurements:
The U24-002-C Data Logger supports the following measurements:
Temperature • Conductivity/Salinity
IMPORTANT:
This HOBO data logger requires HOBOware Pro software and a communications device. See compatible items below.


Feature

  • Non-contact sensor provides long life
  • Provides easy access to sensor for cleaning and shedding air bubbles
  • Two user-selectable ranges provide measurements from 100 to 55,000 uS/cm.
  • The Delrin housing will not corrode in saltwater
  • HOBOware Pro software enables start/end-point calibration to compensate for any fouling and provides easy conversion to specific conductance and salinity using the Practical Salinity Scale 1978 (PSS-78)
  • USB optical interface provides high-speed, reliable salinity data offload in wet environments
  • Compatible with the HOBO Waterproof Shuttle for easy and reliable data retrieval and transport

Spesification

Measurements: Actual Conductivity, Temperature, Specific Conductance at 25C (calculated), Salinity (calculated using PSS-78, the Practical Salinity Scale 1978)

Conductivity Measurement Range: (Calibrated Range)
High Range: 5000 to 55,000 uS/cm
Low Range: 100 to 10,000 uS/cm
Over the range of 5 to 35C (41 to 95F)

Temperature Measurement Range: 5 to 35C (41 to 95F)

Plot A: Salinity Range (U24-002-C)*
Plot A: Salinity Range
Plot B: Specific Conductance Range in Saltwater
Plot B: Specific Conductance Range in Saltwater
Plot C:
Specific Conductance High-Range Accuracy (U24-002-C)

Plot D: Specific Conductance High-Range Accuracy (U24-002)

Specific Conductance Accuracy: (in Calibrated Range using Conductivity Assistant and Calibration Measurements)

Low Range: 3% of reading or 50 µS/cm, whichever is greater
High Range: 5% of reading, in waters within a range of
±3,000 µS/cm; waters with greater variation can have substantially greater error (see Plot C)

Resolution:
Conductivity: 2 uS/cm
Temperature: 0.01°C (typical 0.02°F)

Conductivity Drift:
Up to 12% sensor drift per month, exclusive of drift from fouling. Monthly start- and end-point calibration should be used with the HOBOware Conductivity Assistant to achieve the specified Specific Conductance accuracy.

Response time: 1 second to 90% of change (in water)

Operating Range: -2 to 36C (28 to 97F) – non-freezing

Memory: 18,500 temperature and conductivity measurements when using one conductivity range; 14,400 sets of measurements when using both conductivity ranges (64kbytes)

Sample rate: 1 second to 18 hrs, fixed or multiple-rate sampling with up to 8 user-defined sampling intervals

Clock accuracy: +/- 1 minute per month

Battery life: 3 years (@ 1 min logging)

Maximum Depth: 70 m (225')

Weight: 193 gm (6.82 ounces), buoyancy in freshwater: -59.8 gm (-2.11 ounces)

Size: 3.18 cm diameter x 16.5 cm, with 6.3 mm mounting hole (1.25" diameter x 6.5", ¼" hole)

Wetted Housing Materials: Delrin housing, epoxy, stainless steel retaining ring, polypropylene, Buna rubber O-ring, titanium pentoxide (inert coating over sensor) – all materials are suitable for long-term use in saltwater.

CE Compliance: The CE Marking identifies this product as complying with all relevant directives in the European Union (EU).

Inquiry

Name :
Company :
Address :
Email :
Handphone :
Subject :
Product Name :
Product Type :
Message :
   

Video

Testimoni


Artikel Terkait dengan Produk Conductivity/Salinity Data Logger HOBO - U24-002-C


NEWSLETTER

 

TESTIMONIALS

B2TKS

B2TKS
Sangat jarang perusahaan seperti ini di Indonesia!  Mereka terus-menerus mengikuti perkembangan inovasi engineering test & measurement, “nyambung” berdiskusi teknis dan berpengalaman, memiliki visi pengembangan teknologi pengukuran, pengujian, inspeksi dan monitoring.(Dr.-Ing. Ir. May Isnan - NDT Specialist B2TKS-BPPT)

Chevron

Chevron
Tim kerja Alat Uji dapat diandalkan. Sangat bagus dalam implementasi di lapangan. Secara umum kami puas dengan services nya!(Andre - HSE Chevron)

BPPT

BPPT
Saya baru sekali ini bertemu perusahaan engineering yang eksis seperti ini di Indonesia.  Sangat terbantu dengan solusi yang diberikan, sangat memuaskan!(Muksin Saleh, ST., MT - Fuel Conversion and Pollution Control Specialist, B2TE - BPPT)

BALITBANG

BALITBANG
Sistem monitoring yang disuplai oleh Alat Uji adalah yang tertinggi ratingnya sampai dengan saat ini dibandingkan sistem lain yang pernah kami miliki, Dengan sistem monitoring dari Alat Uji, Pengujian kami jadi lebih terkontrol karena ada visualisasi di sistemnya. (Gatot Sukmara - Badan Penelitian dan Pengembangan, Departemen Pekerjaan Umum)

 
Alat Uji Alat Uji Alat Uji Alat Uji Alat Uji Alat Uji