Compressed Air Flow Meter - T-CDI-5200-10S
The T-CDI-5200-10S is a flowmeter for compressed air systems. It measures flow by maintaining one probe warmer than the other. It calculates the mass velocity from the amount of heat required, and then calculates the flow on the basis of pipe area. This model fits 1" steel pipes.
Requires analog port selection during U30 system configuration and use of a S-FS-CVIA when using the H22-001 logger. When using a U12 logger, this sensor requires a 4-20mA input cable (CABLE-4-20mA).
Feature
- This adds the ability for users to be able to measure compressed air flow (SCFM).
- Easy to install
- Digital display
Spesification
Measurement range, 5200 model | 1 - 80 SCFM |
Measurement range, 5400 model | 3 - 350 SCFM (calibrated), 350 - 600 (uncalibrated) |
Accuracy | (5200 model) 5% of reading plus 1% of full scale @ air temperatures 40 - 120F |
Accuracy | (5400 model calibrated range) 5% of reading plus 1% of full scale @ air temperatures 40 - 120F; (5400 model extended range) 7% of reading from rated fule scale to 150% of calibrated range, @ air temperatures 40 - 1200F Medium: Compressed air, nitrogen |
Operating pressure, 5200 model | 30 to 170 psig for best accuracy. 200 psig max on Sch 40 steel |
Operating pressure, 5400 model | 200 psig max on Sch 40 steel |
Input power | 250 mA @ 18 - 24 VDC |
Output resistance | 400Ω max |
Response time | 1 sec to 63% of final value |
Output | selectable 4 - 20mA or pulse |
Display | 4-digit LED |