VIBRATION METER Multi Channel Model-1607a
This a VIBRATION METER as Small charge vibrometer capable of multichannel simultaneous measurement. General-purpose type small vibrometer capable of measuring three modes of acceleration, velocity and displacement. Wide-band and capable of measuring from a minute level to a large level. Capable of selecting a band matching a measurement object because of the built-in high-pass/low-pass filter. Capable of appropriately using various sensors with ease by the easy setting of the sensor’s sensitivity. Capable of using a remote charge converter and a detector with a built-in preamp in addition to an ordinary charge-output type detector.
Feature
3CH mounted | ||||
Amp Unit | MODEL-1607A | 3pc | ||
Power Supply Unit | MODEL-1607A-10M | 1pc | ||
Channel Case | MODEL-1607A-23 | 1pc | ||
Instruction manual | 1copy | |||
*Capable of multichannel, max. 10-channel. |
Spesification
Input Rear Panel BNC Connector, Charge-Output Sensor/ Built-in Preamp | ||
Charge input | PU SENS×1:1.00-9.99pC/G | |
PU SENS×10:10.0-99.9pC/G | ||
Max input charge | 10,000pC | |
Voltage Input Connector | PU SENS×1:1.00-9.99mV/G | |
PU SENS×10:10.0-99.9mV/G | ||
Max input voltage | ±10V | |
Supply current | 2mA, 15VDC(0.4-4mA) | |
Output | ||
AC OUT(BNC) | Vibration waveform output | |
±1V/FS Output resistance 100Ω 5mA Max.current | ||
DC OUT(BNC) | Trend recording as level output | |
0-1VDC Output resistance 100Ω 5mA Max.current | ||
Overload lamp | When the linear range is exceeded in the internal circuit, LED lamp is on. |
|
Measuring Range | ||
ACC1(G) | 1Hz-50kHz(1dB), 2Hz-20kHz(0.5dB) | |
PU SENS×10:0.0316/0.1-100/316/FS | ||
PU SENS×1:0.316/1-1000/3160/FS | ||
ACC2(m/s2) | 1Hz-50KHz(1dB), 2Hz-20kHz(0.5dB) | |
PU SENS×10:0.316/1-1000/3160/FS | ||
PU SENS×1:3.16/10-10000/31600/FS | ||
VEL(cm/s) | 3Hz-(0.5dB) | |
PU SENS×10:0.316/1-1000/3160/FS | ||
PU SENS×1:3.16/10-10000/31600/FS | ||
DISP(mm) | 3Hz-(0.5dB) | |
PU SENS×10:0.1/0.316-316/1000/FS | ||
PU SENS×1:1/3.16-3160/10000/FS | ||
DISP2(mm) | 10Hz-(0.5dB) | |
PU SENS×10:0.01/0.0316-31.6/100/FS | ||
PU SENS×1:0.1/0.316-316/1000/FS | ||
Filter | ||
High-pass filter(Hz) | OUT(1Hz)/3/10/30/100 | |
Low-pass filter(Hz) | 300/1k/3k/10k/OUT(50KHz) | |
The Others | ||
Accuracy | Within 3% at 80Hz,100pC input | |
Cal signal | 80Hz,±1V max. sinusoidal wave | |
Temperature, Humidity | 0-50ºC,90%RH max. | |
Dimensions, weight | 35(W)×177(H)×230(D)mm 0.7kg | |
Power Supply Unit MODEL-1607A-10M | ||
AC100V ±10%, CAL signal:80Hz ±1V sinusoidal wave, 10CH selectable monitor meter. | ||
Dimensions, weight | 90(W)×177(H)×230(D)mm 1.1kg | |
Channel Case, weight | 3CH- 1.8kg 6CH- 2.5kg |
Inquiry
Video
Tidak ada video untuk produk ini